Sunbird off grid bi directional solar inverter is the new generation inverter, which has been designed specially for the solar application. Our long standing Two decade expertise in solar On Grid and Off grid inverter market has resulted in to a smart, more reliable and efficient Sunbird Solar Inverter. Sunbird Solar inverter has many unparallel features, which gives best ROI for the user and helps in bringing the dream of Green planet more closer.

TECHNICAL SPECIFICATIONS

System Rating(kVA) 10 15 20 25 30 40/50 80/100
PHOTOVOLTAIC INPUT
MPPT Range 165 - 200 V 330 - 420 V
Open Circuit Voltage (Voc) 300 V 600 V
Maximum PV power recommended (KW) 11 16.5 22 27.5 33 44/55 88/110
MPPT base Charge Controller
Switching Element MOSFET IGBT
Controller 32 Bit DSP controlled
Type of Charger PWM with MPPT
Grid Input
Input Supply 415 V AC , 50Hz (-20%, +15%), 3 Phase 4 Wire
Active Filtering during load on mains
(Load Harmonic corrections) THDi up to 3 % & Power Factor > 0.99
BATTERY
Battery Voltage 120 V 240 V
Grid through Battery charging capacity (%kw Rating) 0 - 100%
INVERTER
Switching Element IGBT 240 V
Control 32 Bit DSP controlled
Nominal Output Voltage, Frequency 415 V AC L - L, 50 Hz, 3 Phase 4 Wire
Output Waveform Sine Wave
Load Power Factor 0.6 lag to 1 ( within kVA and kW rating)
Voltage Regulation ± 2%
Voltage Stability in dynamic condition Complies with IEC/EN 62040-3,Class 1
Output voltage distortion with 100% linear load < 2%
Inverter peak efficiency (Ref. STD IEC 61683) 92% 94%
Protection degree with open doors IP 20
Colour RAL 7016, Texture
Dimension (WxDxH in mm) 600 x 800 x 1200 600x800x1750 1000x900x1750
Galvanic Isolation Inbuilt isolation transformer at inverter output
Protection Under/Over voltage for Input, Output, Array & Battery. Output overload, short circuit, Over temperature, MCCB at Input, Output, Array & Battery path.& Surge protection at Input, Array & Battery path.
Display Parameter 1. Array - Voltage, Current, Power, Temperature, 2. Battery - Voltage, current, Power. 3. Grid - Voltage, Current, Power, PF, 4. Output - Voltage, Current, Inv. H/S temp. 5. Statistics - Grid import, Grid export, Total Output, Daily Output Power, kWH
ENVIRONMENT
Temperature Operating 0 to 40° C
Max. Relative humidity @ 25°C (non condensing) Up to 95%
Max. Altitude above sea level without de-rating 1000 m (For higher altitude complies with IEC/EN 62040 - 3)
Standard Compliance
Testing IEC 62040-3 ; IEC 61683 ; 60068-2
Specifications are subject to change without prior notice due to constant improvement in design & technology
Custom models available on request